RKI  |  SKU: 721-001

RKI Eagle 2 Single Gas Portable Monitor for LEL, O2, H2S, CO2, VOC PID & Toxics

$2,037.75 $2,145.00
Shipping calculated at checkout.
No reviews


Description

If you need a different configuration please do not hesitate to contact us. We can help you find the ideal configuration for your RKI Eagle 2.

RKI Eagle 2 Single Gas Portable Monitor

The EAGLE 2 is the solution for just about any portable gas monitoring situation. Equipped with features that are not available on competitive units, the EAGLE 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. The EAGLE 2 offers easy access to controls such as auto-calibration, alarm silence, demand zero, peak hold, and methane elimination. Each channel has two alarm levels plus TWA and STEL alarms for toxic channels. The two alarm levels are user adjustable and can be latching or self resetting.

The EAGLE 2 available features include a PID sensor for detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases; % volume capability for CH4 and H2 using a TC  (thermal conductivity) sensor; PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % volume), methane or hydrocarbons in LEL and % volume ranges; methane elimination feature for environmental applications; and a variety of super toxic gases. The EAGLE 2 has a strong internal pump with a low flow auto pump shut off and alarm, which can draw samples from up to 125 feet. This allows for quick response and recovery from distant sampling locations. The EAGLE 2 will continuously operate for over 18 hours on alkaline batteries or 20 hours on NiMH. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, just to name a few. Data-logging is a standard feature for all sensors on all versions.

The Eagle 2 is ideal for performing EPA Method 21 fugitive emission monitoring of VOC leaks from process equipment.. EPA Method 21- Determination of Volatile Organic Compound Leaks, is a test method used for the determination of leaks of VOCs from process equipment. The Eagle 2 meets the requirements for portable instruments used for this purpose as outlined in Sections 6 and 8 of Method 21.

Specialty Sensors

The PID sensor is capable of detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases. Other smart sensors include % volume capability for CH4 and H2 using a TC (thermal conductivity) sensor; ppm or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % volume), methane or hydrocarbons in LEL and % volume ranges; Optional LEL / ppm H2 specific sensor, methane elimination feature for environmental applications; and a variety of super toxic gases. EAGLE 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. Made In U.S.A

  • PID (Photoionization Detector)
    • Low or high range for VOC detection
    • Humidity and contamination resistant
  • Infrared (IR) CO2, % LEL CH4, % Vol. CH4, % LEL HC, % Vol. HC
  • Thermal Conductivity (TC) % Vol. H2, % Vol. CH4
  • Smart toxic, plug and play sensors NH3, AsH3, Cl2, HCN, PH3, & SO2

 

RKI EAGLE 2 Data Sheet PDF

RKI Eagle 2 Operator's Manual

 

RKI Eagle 2 Training Video


Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Have questions? Contact us using the form below.

RKI Eagle 2 Single Gas Portable Monitor for LEL, O2, H2S, CO2, VOC PID & Toxics - Carbon Bulk Sales
RKI

RKI Eagle 2 Single Gas Portable Monitor for LEL, O2, H2S, CO2, VOC PID & Toxics

From $2,037.75 $2,145.00

If you need a different configuration please do not hesitate to contact us. We can help you find the ideal configuration for your RKI Eagle 2.

RKI Eagle 2 Single Gas Portable Monitor

The EAGLE 2 is the solution for just about any portable gas monitoring situation. Equipped with features that are not available on competitive units, the EAGLE 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. The EAGLE 2 offers easy access to controls such as auto-calibration, alarm silence, demand zero, peak hold, and methane elimination. Each channel has two alarm levels plus TWA and STEL alarms for toxic channels. The two alarm levels are user adjustable and can be latching or self resetting.

The EAGLE 2 available features include a PID sensor for detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases; % volume capability for CH4 and H2 using a TC  (thermal conductivity) sensor; PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % volume), methane or hydrocarbons in LEL and % volume ranges; methane elimination feature for environmental applications; and a variety of super toxic gases. The EAGLE 2 has a strong internal pump with a low flow auto pump shut off and alarm, which can draw samples from up to 125 feet. This allows for quick response and recovery from distant sampling locations. The EAGLE 2 will continuously operate for over 18 hours on alkaline batteries or 20 hours on NiMH. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, just to name a few. Data-logging is a standard feature for all sensors on all versions.

The Eagle 2 is ideal for performing EPA Method 21 fugitive emission monitoring of VOC leaks from process equipment.. EPA Method 21- Determination of Volatile Organic Compound Leaks, is a test method used for the determination of leaks of VOCs from process equipment. The Eagle 2 meets the requirements for portable instruments used for this purpose as outlined in Sections 6 and 8 of Method 21.

Specialty Sensors

The PID sensor is capable of detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases. Other smart sensors include % volume capability for CH4 and H2 using a TC (thermal conductivity) sensor; ppm or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % volume), methane or hydrocarbons in LEL and % volume ranges; Optional LEL / ppm H2 specific sensor, methane elimination feature for environmental applications; and a variety of super toxic gases. EAGLE 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. Made In U.S.A

 

RKI EAGLE 2 Data Sheet PDF

RKI Eagle 2 Operator's Manual

 

RKI Eagle 2 Training Video


Models

  • 721-001 - LEL & PPM
  • 721-001-H2 - LEL & PPM (Hydrogen (H2) specific)
  • 721-001-IR - LEL Methane only with IR Sensor
  • 721-001-T - LEL / PPM with teflon hose for heavy hydrocarbons
  • 721-001-TT - LEL / PPM Tank Tester version float probe included
  • 721-002 - O2 (0 - 40% volume)
  • 721-002-M - O2 (0 - 40% volume) marine version with internal oil mist filter
  • 721-003 - Hydrogen Sulfide (H2S) 0 - 100 ppm
  • 721-005 - Sulfur Dioxide (SO2) 0 - 6.0 ppm
  • 721-006 - Chlorine (Cl2) 0 - 3 ppm
  • 721-007 - Arsine (AsH3) 0 - 1.5 ppm
  • 721-008 - Phosphine (PH3) 0 - 1.0 ppm
  • 721-011 - Ammonia (NH3) 0 - 75 ppm
  • 721-015-02 - Carbon Dioxide CO2 (0 - 10000 ppm)
  • 721-015-03 - Carbon Dioxide CO2 (5% volume)
  • 721-015-05 - Carbon Dioxide CO2 (60% volume)
  • 721-020 - Methane (CH4) (100% LEL / 100% volume (IR) autoranging)
  • 721-021 - Hydrocarbons (HC) 100% LEL / 30% volume (IR) autoranging
  • 721-023 - Hydrogen Cyanide (HCN) 0 - 15 ppm
  • 721-101-P1 - VOC’s 0 - 50 ppm (PID)
  • 721-101-P2 - VOC’s 0 - 2000 ppm (PID)
  • 721-102-10 - Hydrogen H2 10% volume (TC)
  • 721-102-20 - Hydrogen H2 100% volume (TC)
  • 721-102-30 - Methane 0 - 100% volume (TC)
View product